Despite recent advances in acute renal failure (ARF) definition, diagnosis, and treatment many aspects remain subject to controversy and lack of consensus. Renal replacement therapies (RRT) are an important part of this ongoing debate, and although modern technology has made a vast pool of different strategies of extracorporeal renal support easily available, it is still not clear which one is superior to the other in terms of efficacy and outcome. Moreover, evidence-based medicine has not yet defined the best time to prescribe RRT and when and how patients should be weaned from this therapy. This chapter will review most of these aspects and will provide some theoretical and practical bases for RRT prescription with the goal of helping intensive care unit (ICU) clinicians understand critical care nephrology.

Acute Renal Failure and the Critically Ill Patient

A recent multinational, multicenter prospective epidemiologic survey of ARF was conducted in ICU patients who either were treated with RRT or fulfilled at least one of the predefined criteria for ARF (1). Predefined ARF criteria were oliguria, defined as urine output less than 200 mL in 12 hours, and/or marked azotemia, defined as a blood urea nitrogen level higher than 30 mmol/L. The data were collected at 54 hospitals in 23 countries. Of 29,269 critically ill patients admitted during the 16 month study period, 1,738 (5.9%) had ARF during their ICU stay, including 1,260 (4.3%) who were treated with RRT. Overall hospital mortality was 60.3%. The most common contributing factor to ARF was septic shock (47.5%). Approximately 30% of patients had preadmission renal dysfunction; 86.2% survivors were independent from dialysis at hospital discharge. Independent risk factors for hospital mortality included the use of vasopressors, mechanical ventilation, septic shock, cardiogenic shock, and hepatorenal syndrome.

Crude mortality assessment shows that the overall hospital outcome of ARF has remained high today, and it has not changed in the last 30 years; nevertheless, such analysis is profoundly misleading. Patients with ARF 30 years ago were mostly treated outside the ICU, did not require or receive mechanical ventilation or vasopressor drugs, were 20 to 30 years younger in age, and their outcome was typically assessed retrospectively and in academic centers. Despite such profound differences that indicate a much greater illness severity for patients treated in 2005, the mortality of ARF has not increased, and perhaps has slightly decreased. The duration of treatment has clearly decreased in terms of need for dialysis, as well as the patient's stay in the ICU and hospital, and the techniques of artificial renal support have also changed markedly (2). It is a matter of fact, however, that 50% to 60% crude mortality associated with ARF will remain unchanged in the next decade. In fact, as therapeutic capability improves and the system continues to accept a mortality of 50% as reasonable for these very sick patients, the health care system will progressively admit and treat sicker and sicker patients with ARF.

In modern health care systems, hence, ARF and the requirement for acute RRT have become an established reality. It has been estimated that the incidence of ARF requiring extracorporeal support is 11.0 per 100,000 population/year. The annual mortality rate is 7.3 per 100,000 residents, with the highest rates in males older than 65 years. Renal recovery occurs in 78% (68/87) of survivors at 1 year, meaning that, although a great number of patients with severe ARF will proceed to die, most survivors will become independent from RRT within a year (3). The number of acute dialytic treatments has grown up to the development of a new specialized branch of nephrology in the last 10 years: however, it is important to emphasize that a critically ill patient with ARF is not a patient with isolated renal dysfunction. ARF requires a multidisciplinary approach with intensivists and nephrologists sharing their respective knowledge. Fluid balance, vasopressor dosage, mechanical ventilation support, and arterial blood gas exchange—including PaO2/FIO2 (partial pressure of oxygen/inspired fraction of oxygen) ratio—need to be associated to RRT prescription, dialysis dose, ultrafiltration requirement, and anticoagulation strategy. Younger ICU clinicians need an in-depth understanding in their routine practice of all theoretical and technical aspects of critical care nephrology.

Historical Notes

From the initial description of continuous arteriovenous hemofiltration (CAVH) in 1977 by Peter Kramer et al. (4), RRT has progressively evolved in the ICU from a last-chance therapy for ARF to a standardized, widely used, fully independent form of artificial kidney support. Hardware and software technology supporting the application of RRT has greatly improved. The trend of this evolution and the potential of RRT have grown to a point in which multiple organ support therapy (MOST) is envisaged as a possible therapeutic approach in the critical care setting.

CAVH was the first example of artificial renal support applied to critically ill patients (Fig. 161.1A); this mode was capable of overcoming the traditional hemodialysis side effects, making possible the treatment of critically ill patients who previously could not be treated because of severe instability.

Hypotension due to rapid fluid removal, arrhythmias caused by rapid electrolytes and intravascular volume shifts, and cerebral edema in head-injured patients were just some of the typical complications occurring during traditional dialysis therapies. The clinical picture was further worsened by the fast reduction of plasma osmolality induced by hemodialysis. CAVH provided slow, continuous fluid removal while maintaining steady solute concentrations and preventing peaks of toxic substances. At the same time, the advent of CAVH coincided with the establishment of fully staffed, independent intensive care units. In some of these units, renal replacement therapy could even be performed in the absence of a nephrology or a dialysis team. CAVH, however, had serious limitations. It required arterial access routinely associated with technical problems and high morbidity. Solute clearance was limited by the low rates of ultrafiltration and the pure convective nature of the treatment. Ultrafiltration limitation was imposed by the relatively low blood flow in the circuit, driven by a spontaneous arteriovenous pressure gradient and low transmembrane pressure (TMP) gradient. The first was dependent on the mean arterial pressure of the patient and the intrinsic resistance of the circuit; the second was determined by the hydrostatic pressure drop inside the filter and the negative suction provided by the ultrafiltrate column from the patient level to the ground. This meant that the most hemodynamically unstable patients achieved the lowest clearances and presented early clotting of the circuit. Technical improvements of CAVH (suction in the ultrafiltrate side, predilution, supplementation of countercurrent dialysate flow) allowed it to exceed 20 mL/minute of clearance, hardly sufficient to meet the needs of severely catabolic patients. To overcome such technical limitations, new filters were designed with an increased cross-sectional area and inner hollow fiber diameter, reduced unit length, and lower resistance to blood flow; by these measures, the phenomenon of filtration pressure equilibrium and easy clotting due to poorly optimized ultrafiltration profile was diminished, if not avoided. Another option explored in those days was the use of highly biocompatible membranes mounted on parallel plate devices. These filters presented lower intrinsic resistance (ensuring higher extracorporeal blood flows at a given arteriovenous pressure gradient), and they were equipped with a second port in the filtrate compartment so that countercurrent dialysate flow could be programmed in the newly conceived continuous arteriovenous hemodiafiltration (CAVHD) mode.

Figure 161.1. A: Continuous arteriovenous hemofiltration: artery and vein are cannulated; blood flow depends on pressure gradient; ultrafiltration is spontaneous and is mostly a function of ultrafiltrate column from the patient level to the effluent bag. B: Early example of pump systems applied to renal replacement therapy: the “Christmas tree–like effect”.

The evolution of technology and the progress experienced in the ICU made it possible to activate renal replacement therapy programs in several institutions, even in the absence of a chronic dialysis facility or a trained nephrologic team. Initial limitations and drawbacks of CAVH stimulated nurses and physicians to explore new avenues for better outcome of the therapy. The logical evolution was to apply a peristaltic pump to the extracorporeal circuit. It must be reminded that the use of a blood pump in the ICU was considered in those days as a proprietary technology of the dialysis team (nurses and nephrology consultants) and a technology that required a specific expertise. Eventually, the knowledge of pumped systems began to be disseminated in the critical care world, making venovenous hemofiltration a reality. The need of hardware evolution in CAVH was not limited to blood pumps, but it was also extended to fluid delivery systems and ultrafiltration control mechanisms such that it allowed delivery of dialysate or replacement solutions with an acceptable degree of accuracy.

The first step toward continuous venovenous renal replacement therapies was the advent of double lumen catheters that made possible the puncture of a single vein, thus decreasing the high rate of complications due to the need of arterial cannulation. The driving force was no longer produced by the patient's mean arterial pressure, but resulted from the mechanical action of the roller pumps. Blood flows could finally be programmed and delivered with adequate precision. Nevertheless, the new configuration of the extracorporeal circuit brought with it the requirement for new accessories and new safety features that were mostly borrowed from the chronic hemodialysis technology. The continuous venovenous therapy setup required negative pressure measurement and alarm in the arterial line before the pump, as well as positive pressure measurement and alarm in the venous return line. In this line, a bubble trap had to be inserted to prevent air embolism (this was not necessary in CAVH where the circuit operated at positive pressure along the entire length of the system). The higher blood flows induced higher filtration rates and the possibility to exploit higher clearances because of increased dialysate flow rates. For this reason, roller pumps were also applied to the dialysate or fluid replacement delivery section of the circuit, and external scales had to be frequently used to provide sufficiently accurate fluid balance during treatment.

The benefits induced by the new adaptive technology were soon counterbalanced by the gross inaccuracy of the systems and the limited integration between the extracorporeal circuit and the fluid balance devices. Furthermore, the fact that these combined devices were mostly derived from the chronic dialysis world conflicted with the possibility of their adequate usage in continuous and prolonged treatment. Finally, the need of obtaining additional information or performing additional functions led physicians and nurses to include in the system several other devices often poorly integrated, with the final result of a cumbersome Christmas tree–like effect (Fig. 161.1B). Safety and performance were definitely not optimized. Blood pumps were often inaccurate, circuit tubing was damaged over time, uncontrolled filtration fractions resulted because of pressure and flow fluctuations, intrafilter hematocrit and platelet count consequently increased beyond safe values, and filter clotting typically occurred. Accurate ultrafiltration control is mandatory in modern RRT. Early machines did not have scales or pumps, and when volumetric pumps started to be used to drive dialysate and ultrafiltrate in and out from the filters, inaccuracies close to 10% were observed, an unacceptable error during 24-hour-long therapies. Furthermore, when the membrane was clogged and approaching failure, the ultrafiltrate volumetric pump was increasing its inaccuracy because of the wide fluctuation in the membrane ultrafiltration coefficient. It soon became evident that an ideal extracorporeal circuit should have incorporated continuous pressure measurements of the inlet and outlet lumen of the catheter, inlet and outlet of the filter, and ultrafiltrate and dialysate ports. When this information was integrated with adequate alarms, it resulted of crucial importance, and allowed the ICU staff to maintain filter efficiency and circuit patency, detect potential sources of clotting, and ensure patient safety.

Indications for Initiation and Cessation of Renal Replacement Therapy

General Indications

Uremic complications of ARF such as pulmonary edema, severe fluid overload, hyperkalemia-induced arrhythmias, and uncontrolled metabolic acidosis have long been described. Nonetheless, there are no predefined established indications on when to start RRT. Medical management attempts to prevent renal dysfunction include the use of diuretics, bicarbonate, fluid restriction, and nutritional restriction to control hyperkalemia. When these attempts fail, treatment is escalated to RRT. In recent times, a more aggressive blood purification approach has been advocated, with the maintenance of homeostasis and prevention of complications being a priority for the critically ill patient (5). Now that multiple RRT options are easily available in the ICU and little morbidity is described in association with the administration of extracorporeal renal support, early blood purification is desirable, and a prevention-based algorithm for initiation of RRT can be used (Table 161.1). Unfortunately, once RRT has started, there is no scientifically established biochemical or clinical marker that should be targeted by the therapy. A routine clinical practice is to maintain urea concentration below 30 mg/dL, creatinine below 2.5 mg/dL, and electrolytes within normal values.

Techniques and timing of weaning patients from RRT are poorly described in the literature. Again, following practical clinical concepts, it is recommended that when the patient has reached hemodynamic stability, and/or the need for vasopressors has been reduced and/or the severity of illness has decreased, intensity of the blood purification can be decreased. If the patient was on a continuous schedule, he or she can be switched to an intermittent or semicontinuous modality. This process can be accelerated when urine output and fluid balance become adequate. Current research focuses on the possibility of classifying ARF according to multilevel classification (see below) and applying it to administer renal supportive therapies, depending on the level of the disease.

Table 161.1 Indications for Starting RRT

The presence of one indication suggests, two indications strongly suggest, three indications mandate initiation of RRT.

· Anuria/oliguria (diuresis ≤200 mL in 12 h)

· Severe metabolic acidosis (pH <7.10)

· Hyperazotemia (BUN ≥80 mg/100 mL) or creatinine >4 mg/dL

· Hyperkalemia (K+ ≥6.5 mEq/L)

· Clinical signs of uremic toxicity

· Severe dysnatremia (Na+ ≤115 or ≥160 mEq/L)

· Hyperthermia (temperature >40°C without response to medical therapy)

· Anasarca or severe fluid overload

· Multiple organ failure with renal dysfunction and/or systemic inflammatory reaction syndrome, sepsis or septic shock with renal dysfunction

Controversies

A clear ARF consensus definition is needed that would allow clinicians to better classify epidemiology, randomizing patients in controlled trials, testing therapies in similar groups of patients, developing animal models, and validating diagnostic tests. To make consensus-based recommendations and delineate key questions for future studies, the Acute Dialysis Quality Initiative (ADQI) work group in 2004 identified the need for a definition/classification system for ARF as a topic related to the field of ARF and ranked this need first for importance and clinical impact (6). The work group considered that the definition of ARF necessarily required the following features:

· Ease of use and clinical applicability across different centers

· High sensitivity and specificity for different populations and research questions

· Consideration of creatinine changes from baseline

· A classification for acute or chronic renal disease

Figure 161.2. The RIFLE classification separates criteria for serum creatinine and urine output (UO). The criteria that lead to the worst possible classification should be used. RIFLE-F is present even if the increase in serum creatinine is below threefold, as long as the new serum creatinine is 4.0 mg/dL (350 mmol/L) or above in the setting of an acute increase of at least 0.5 mg/dL (44 mmol/L). The shape of the figure denotes the fact that more patients (high sensitivity) will be included in the mild category, including some not actually having renal failure (less specificity). In contrast, at the bottom, the criteria are strict and therefore specific, but some patients will be missed. ARF, acute renal failure; GFR, glomerular filtration rate. (From Bellomo R, Ronco C, Kellum JA, et al., and the ADQI workgroup. Acute renal failure—definition, outcome measures, animal models, fluid therapy and information technology needs: the Second International Consensus Conference of the Acute Dialysis Quality Initiative [ADQI] Group. Crit Care. 2004;8:R204–R212, with permission.)

Such a classification would include and separate mild and severe as well as early or late cases, and would allow the detection of patients in whom renal function is mildly affected (high sensitivity for the detection of kidney malfunction but limited specificity for its presence) and patients in whom renal function is markedly affected (high specificity for true renal dysfunction but limited sensitivity in picking up early and more subtle loss of function). Accordingly, a multilevel classification system was proposed for a wide range of conditions such as Renal dysfunction, Injury to the kidney, Failure or Loss of kidney function, and End-stage kidney disease; these criteria are identified by the acronym RIFLE (Fig. 161.2).

When such classification achieves sufficient clinical validation (7), it will be reasonable to couple each level of ARF severity to a specific management plan (medical or artificial) and/or to identify a RRT modality/prescription for that level of renal dysfunction. In our experience, a RIFLE-F level (Fig. 161.2) of ARF severity could be a reasonable trigger to start RRT apart from any previously attempted medical therapy.

Continuous, Intermittent, Diffusive, Convective: an Ongoing Matter

RRT Modalities: Description and Nomenclature

Renal replacement consists of the purification of blood by semipermeable membranes. A wide range of molecules, from water to urea to low-, middle-, and high-molecular-weight solutes, is transported across such membranes by the mechanism of ultrafiltration (water), convection, and diffusion (solutes) (Fig. 161.3).

During diffusion, the movement of solutes depends on their tendency to reach the same concentration on each side of the membrane; the practical result is the passage of solutes from the compartment with the highest concentration to the compartment with the lowest concentration. Other components of the semipermeable membrane deeply affect diffusion: thickness and surface, temperature, and diffusion coefficient. Dialysis is a modality of RRT and is predominantly based on the principle of diffusion: a dialytic solution flows through the filter countercurrent to blood flow to maintain the highest solute gradient from inlet to outlet port.

During convection, the movement of solute across a semipermeable membrane takes place in conjunction with significant amounts of ultrafiltration (water transfer across the membrane). In other words, as the solvent (plasma water) is pushed across the membrane in response to the transmembrane pressure (TMP) by ultrafiltration (UF), solutes are carried with it, as long as the porosity of the membrane allows the molecules to be sieved from blood. The process of UF is governed by the UF rate (Qf), the membrane UF coefficient (Km), and the TMP gradient generated by the pressures on both sides of the membrane, according to the following formula:

Qf = Km × TMP

Figure 161.3. Diffusion and convection are schematically represented. During diffusion, solutes flux (Jx) is a function of solutes concentration gradient (dc) between the two sides of the semipermeable membrane, temperature (T), diffusivity coefficient (D), membrane thickness (dx), and surface area (A) according to the following equation:

Convective flux of solutes (Jf) requires instead a pressure gradient between the two sides of the membrane (transmembrane pressure, TMP) that moves a fluid (plasma water) with its crystalloid content (a process called ultrafiltration, whose entity is also dependent on the membrane permeability coefficient (Kf). Colloids and cells will not cross the semipermeable membrane, depending on the pores' size.

TMP = Pb - Pd - π, where Pb is blood hydrostatic pressure, Pd is hydrostatic pressure on the ultrafiltrate side of the membrane, and π is blood oncotic pressure).

The hydrostatic pressure in the blood compartment is dependent on blood flow (Qb). The greater the Qb, the greater the TMP. In modern RRT machines, UF control throughout the filter is obtained by applying a pump that generates suction to the UF side of the membrane. Modern systems are optimally designed to maintain a constant Qf; it is worth noting that, when the filter is fresh, the initial effect of UF pumps is to retard UF production, generating a positive pressure on the UF side. Thus, TMP is initially dependent only on Qb. As the membrane fibers foul, a negative pressure is necessary to achieve a constant Qf. In this case, a progressive increase of TMP can be observed up to a maximal level in which clotting is likely, membrane rupture may occur, and, above all, solute clearance may be significantly compromised. In fact, if it is true that the size of molecules cleared during convection exceeds that during diffusion, because they are physically dragged to the UF side, it is also true that this feature is seriously limited by the protein layer that progressively closes filter pores during convective treatments (8). A peculiar membrane capacity, defined as adsorption, has been shown to have a major role in higher-molecular-weight toxins (9); however, it should be considered that membrane adsorptive capacity is generally saturated in the first hours from the beginning of the treatment. This observation reflects the minimal impact of the adsorption component on solute clearance, and suggests relying only on the relatively minor effects of mass separation processes such as diffusion and convection (10).

Figure 161.4. Membranes are classified based on their permeability or filtration coefficient (Kf – mL/h/mm Hg) and their sieving coefficient. A high flux (synthetic membrane) will have a higher permeability to water, with optimal use during hemofiltration or hemodiafiltration (prevalently convective treatments) and bigger pore size to let higher–molecular-weight molecules cross the membrane.

As UF proceeds and plasma water and solutes are filtered from blood, hydrostatic pressure within the filter is lost and oncotic pressure is gained because blood concentrates and hematocrit increases. The fraction of plasma water that is removed from blood during UF is called filtration fraction; it should be kept in the range of 20% to 25% to prevent excessive hemoconcentration within the filtering membrane and to avoid the critical point at which oncotic pressure is equal to TMP and a condition of filtration/pressure equilibrium is reached. Finally, replacing plasma water with a substitution solution completes the hemofiltration (HF) process and returns purified blood to the patient. The replacement fluid can be administered after the filter, with a process called postdilution HF. Otherwise, the solution can be infused before the filter to obtain predilution HF, whereas predilution plus postdilution replacement is obtained on mixed infusion of substitution fluids both before and after filtering the membrane. Although postdilution allows a urea clearance equivalent to therapy delivery (i.e., 2,000 mL/hour—see below), predilution, in spite of theoretical reduced solute clearances, prolongs the circuit life span, reducing the hemoconcentration and protein caking effects occurring within filter fibers. Conventional hemofiltration is performed with a highly permeable membrane with a surface area of about 1 m2, steam sterilized, with a cutoff point of 30 kd (Fig. 161.4).

The Concept of RRT Dose

The conventional view of RRT dose is that it is a measure of the quantity of blood purification achieved by means of extracorporeal techniques. As this broad concept is too difficult to measure and quantify, the operative view of RRT dose is that it is a measure of the quantity of a representative marker solute that is removed from a patient. This marker solute is considered to be reasonably representative of similar solutes, which require removal for blood purification to be considered adequate. This premise has several major flaws; the marker solute cannot and does not represent all the solutes that accumulate in renal failure. Its kinetics and volume of distribution are also different from those of such solutes. Finally, its removal during RRT is not representative of the removal of other solutes. This is true both for end-stage renal failure and acute renal failure. However, a significant body of data in the end-stage renal failure literature (11,12,13,14,15,16) suggests that, despite all of the above major limitations, a single solute marker assessment of dialysis dose appears to have a clinically meaningful relationship with patient outcome, and therefore clinical utility. Nevertheless, the HEMO (hemodialysis) Study Group, examining the effect of intermittent hemodialysis (IHD) doses, enforced the concept that “less dialysis is worse,” but failed to confirm the intuition that “more dialysis is better” (16). Thus, if this premise seems useful in end-stage renal failure, it is accepted to be potentially useful in ARF for operative purposes. Hence, the amount (measure) of delivered dose of RRT can be described by various terms: efficiency, intensity, frequency, and clinical efficacy. Each will be discussed below.

The efficiency of RRT is represented by the concept of clearance (K), i.e., the volume of blood cleared of a given solute over a given time. K does not reflect the overall solute removal rate (mass transfer) but, rather, its value normalized by the serum concentration. Even when K remains stable over time, the removal rate will vary if the blood levels of the reference molecule change. K depends on solute molecular size and transport modality (diffusion or convection), as well as circuit operational characteristics (blood flow rate [Qb], dialysate flow rate [Qd], ultrafiltration rate [Qf], and hemodialyzer type and size). K can be normally used to compare the treatment dose during each dialysis session, but it cannot be used as an absolute dose measure to compare treatments with different time schedules. For example, K is typically higher in intermittent hemodialysis (IHD) than continuous renal replacement therapy (CRRT) and sustained low-efficiency daily dialysis (SLEDD). This is not surprising, since K represents only the instantaneous efficiency of the system. However, mass removal may be greater during SLEDD or CRRT. For this reason, the information about the time span during which K is delivered is fundamental to describe the effective dose of dialysis.

The intensity of RRT can be defined by the product of clearance times time (Kt). Kt is more useful than K in comparing various RRTs. A further step in assessing dose must include frequency of the Kt application over a particular period (e.g., a week). This additional dimension is given by the product of intensity times frequency (Kt × treatment days/week = Kt days/week). Kt days/week is superior to Kt since it offers information beyond a single treatment; patients with ARF typically require more than one treatment. This concept of Kt days/week offers the possibility to compare disparate treatment schedules (intermittent, alternate day, daily, continuous). However, it does not take into account the size of the pool of solute that needs to be cleared. This requires the dimension of efficacy.

The efficacy of RRT represents the effective solute removal outcome resulting from the administration of a given treatment to a given patient. It can be described by a fractional clearance of a given solute (Kt/V), where V is the volume of distribution of the marker molecule in the body. Kt/V is an established marker of adequacy of dialysis for small solutes correlating with medium-term (several years) survival in chronic hemodialysis patients (16). Urea is typically used as a marker molecule in end-stage kidney disease to guide treatment dose, and a Kt/VUREA of at least 1.2 is currently recommended. As an example, we can consider the case of a 70-kg patient who is treated 20 hours per day with a postfilter hemofiltration of 2.8 L/hour at a zero balance. The patient's KUREA will be 47 mL/min (2.8 L/hour = 2,800 mL/60 minutes) because we know that during postfilter hemofiltration, ultrafiltered plasmatic water will drag all urea across the membrane, making its clearance identical to UF flow. The treatment time (t) will be 1,200 minutes (60 minutes for 20 hours). The urea volume of distribution will be approximately 42,000 mL (60% of 70 kg, 42 L = 42,000 mL)—that is, roughly equal to total body water. Simplifying our patient's Kt/VUREA, we will have 47 × 1,200/42,000 = 1.34.

However, Kt/VUREA application to patients with ARF has not been rigorously validated. In fact, although the application of Kt/V to the assessment of dose in ARF is theoretically intriguing, many concerns have been raised because problems intrinsic to ARF can hinder the accuracy and meaning of such dose measurement. These include the lack of a metabolic steady state, uncertainty about the volume of distribution of urea (VUREA), a high protein catabolic rate (PCR), labile fluid volumes, and possible residual renal function, which changes dynamically during the course of treatment. Furthermore, delivery of the prescribed dose in ARF can be limited by technical problems such as access recirculation, poor blood flows with temporary venous catheters, membrane clotting, and machine malfunction. In addition, clinical issues such as hypotension and vasopressor requirements can be responsible for solute disequilibrium within tissues and organs.

These aspects are particularly evident during IHD, less so during SLEDD, and even less during CRRT. This difference is due to the fact that, after some days of CRRT, the patient's urea levels approach a real steady state. Access recirculation is also an issue of lesser impact during low efficiency continuous techniques. Finally, because the therapy is applied continuously, the effect of compartmentalization of solutes is minimized and, from a theoretical point of view, single pool kinetics can be applied (spKt/V) with a reasonable chance of approximating true solute behavior. In order to study the use of spKt/VUREA as a feasible methodology for the measurement of CRRT dose and to standardize disparate prescriptions, a software called “Adequacy Calculator for ARF” was recently tested (17). This is a Microsoft Excel-based program (18) that calculates urea clearance and estimates fractional clearance and Kt/VUREA for all RRT modalities. In a prospective study on continuous therapies, the value of clearance predicted by the calculator correlated significantly to the value obtained from direct blood and dialysate determinations during the first 24 treatment hours, irrespective of the continuous renal replacement modality used.

Other dose measurement methods have been used in patients with end-stage renal failure but have not been sufficiently investigated in the setting of ARF. The time-averaged blood urea concentration (TACUREA) is the area under the sawtooth curve produced by intermittent dialysis sessions. TACUREA is a function of dialysis dose and urea generation rate (G) from protein intake. As such, it is not a good indicator of RRT dose, per se. Emerging evidence from patients with end-stage renal failure suggests the importance of using equivalent renal clearance (EKRc). If G and TACUREA are known, EKRc can be calculated by the ratio of total urea removal (equal to G at steady state) and TACUREA. A modification of this equation was described by Gotch as standardized Kt/V (stdKt/V), and it is calculated as the ratio of G and mean weekly urea pretreatment concentrations (MPC) normalized for VUREA (19,20,21). These formulas allow comparisons among the dose measurements of disparate therapies and different frequencies of RRT. However, G, MPC, and TACUREA calculations are less immediate than K, t and VUREA, which seem easier to achieve without formal modeling. Furthermore, G is likely to be extremely variable from day to day in ARF patients. Finally, in patients who might receive only three or four sessions of IHD, the concept of MPC, which requires a parametric distribution of values, is simply statistically incorrect. VUREA is also dynamic and not as easily estimated using anthropometric calculations.

To evaluate VUREA in patients with ARF, Himmelfarb et al. (22) undertook a systematic study in a cohort of 28 patients with ARF. They found that determination of VUREA by different approaches to anthropometric measurements (Watson, 42.5 ± 7.0 L; Hume-Weyer, 43.6 ± 7.1 L; Chertow, 46.8 ± 8.1 L) yielded significantly lower values compared to VUREA determined by physiologic formulae and by bioimpedance (51.1 ± 11.6 L and 51.1 ± 13.3 L, respectively). Finally and more importantly, all measures of VUREA by blood-based kinetics exceeded measurements by any method (7% to 50% difference). These investigators inevitably concluded that estimates of VUREA cannot be reliably used in patients with ARF.

These observations highlight the gross inadequacies of applying end-stage renal failure paradigms to patients with ARF. They also indicate that, unlike in the field of chronic hemodialysis, only major changes in the application of dose (e.g., changing from twice-a-day to daily dialysis) can be reasonably believed to truly deliver a different dose in the setting of ARF. More subtle adjustments, such as prescribing a calculated Kt/V of 1 versus 1.2, can easily be criticized as being within the calculation error for each prescription and not necessarily representing a reliable change in dose delivery. The major shortcoming of the traditional solute marker–based approach to dialysis dose in ARF lies well beyond any methodologic critique of single-solute kinetics-based prescriptions. In patients with ARF, most of whom are in intensive care, a restrictive (solute-based only) concept of dialysis dose seems grossly inappropriate. In these patients, the therapeutic needs that can be, or need to be, affected by the dose of renal replacement therapy are more than the simple control of small solutes as represented by urea. They include control of acid-base value, tonicity, potassium, magnesium, calcium, phosphate, intravascular volume, extravascular volume, temperature, and the avoidance of unwanted side effects associated with the delivery of solute control. In the critically ill patient, it is much more important (e.g., in the setting of coagulopathic bleeding after cardiac surgery) for 10 units of fresh frozen plasma, 10 units of cryoprecipitate, and 10 units of platelets to be administered rapidly without inducing fluid overload (because 1 to 1.5 L of ultrafiltrate are removed in 1 hour) than for Kt/V to be of any particular value. A dose of RRT is aimed toward prophylactic volume control. In a patient with right ventricular failure, ARF, and ARDS who is receiving lung-protective ventilation with permissive hypercapnia and with acidemia, inducing a further life-threatening deterioration in pulmonary vascular resistance, the dose component of RRT that matters immediately is acid-base control and normalization of pH 24 hours/day. The Kt/V (or any other solute-centric concept of dose) is almost just a by-product of such dose delivery. In a young man with trauma, rhabdomyolysis, and a rapidly rising serum potassium already at 7 mmol/L, the dialysis dose is selected to control hyperkalemia. In a patient with fulminant liver failure, ARF, sepsis, and cerebral edema awaiting urgent liver transplantation, and whose cerebral edema is worsening because of fever, the RRT dose is centered on lowering the temperature without any tonicity shifts that might increase intracranial pressure. Finally, in a patient with pulmonary edema after an ischemic ventricular septal defect requiring emergency surgery, along with ARF, ischemic hepatitis, and the need for inotropic and intra-aortic balloon counterpulsation support, the RRT dose mostly concerns removing fluid gently and safely so that the extravascular volume falls while the intravascular volume remains optimal. Solute removal is simply a by-product of fluid control. These aspects of dose must explicitly be considered when discussing the dose of RRT in ARF, for it is likely that patients die more often from incorrect dose delivery of this type than incorrect dose delivery of the Kt/V type. Although each aspect of this broader understanding of dose is difficult to measure, clinically relevant assessment of dose in critically ill patients with ARF should include all dimensions of such a dose, and not one dimension picked because of a similarity with end-stage renal failure. There is no evidence in the acute field that such solute control data are more relevant to clinical outcomes than volume control, acid-base control, or tonicity control.

RRT Prescription

Theoretical Aspects

Despite all the uncertainty surrounding its meaning and the gross shortcomings related to its accuracy in patients with ARF, the idea that there might be an optimal dose of solute removal continues to have a powerful hold in the literature. This is likely due to evidence from ESRD, where a minimum Kt/V of 1.2 three times weekly is indicated as standard (16). However, the benefits of greater Kt/V accrue over years of therapy. In ARF, any difference in dose would apply for days to weeks. The view that it would still be sufficient to alter clinical outcomes remains somewhat optimistic.

Nonetheless, the hypothesis that higher doses of dialysis may be beneficial in critically ill patients with ARF must be considered by analogy and investigated. Several reports in the literature deal with this issue. Furthermore, the concept of a predefined dose is a powerful tool to guide clinicians to a correct prescription and to at least avoid undertreatment.

Brause et al. (23), using continuous venovenous hemofiltration (CVVH), found that higher Kt/V values (0.8 vs. 0.53) correlated with improved uremic control and acid-base balance; this would be expected. No clinically important outcome was affected. Investigators from the Cleveland clinic (24) retrospectively evaluated 844 patients with ARF requiring CRRT or IHD over a 7-year period. They found that, when patients were stratified for disease severity, the dialysis dose did not affect outcome in patients with very high or very low scores but did correlate with survival in patients with intermediate degrees of illness. A mean Kt/V greater than 1.0 or TACUREA less than 45 mg/dL was associated with increased survival. This study was retrospective with a clear post hoc selection bias. Therefore, the validity of these observations remains highly questionable.

Daily IHD compared to alternate-day dialysis also seemed to be associated with improved outcome in a recent trial (25). Daily hemodialysis resulted in significantly improved survival (72% vs. 54%, p = 0.01), better control of uremia, fewer hypotensive episodes, and more rapid resolution of ARF. However, several limitations affected this study: sicker, hemodynamically unstable patients were excluded and underwent CRRT instead. Furthermore, according to reported mean TACUREA, it appears that patients receiving conventional IHD were underdialyzed. In addition, this study was a single-center study with all the inherent limitations in regard to external validity. Furthermore, twice-daily dialysis was associated with significant differences in fluid removal and dialysis-associated hypotension, suggesting that other aspects of dose beyond solute control (inadequate and episodic volume control) may have explained the findings. These observations suggest that further studies should be undertaken to assess the most effective dose of IHD on outcome.

In a randomized controlled trial of CRRT dose, continuous venovenous postdilution hemofiltration (CVVH) at 35 mL/kg/hour or 45 mL/kg/hour was associated with improved survival when compared to 20 mL/kg/hour in 425 critically ill patients with ARF (26). Applying Kt/V dose assessment methodology to CVVH, at a dose of 35 mL/kg/hour in a 70-kg patient treated for 24 hours, a treatment day would be equivalent to a Kt/V of 1.4 applied daily. Despite the uncertainty regarding the calculation of VUREA, CVVH at 35 mL/kg/hour would still provide an effective daily delivery of 1.2, even in the presence of an underestimation of VUREA by 20%. Many technical and/or clinical problems, however, can make it difficult in routine practice to apply such strict protocol by pure postdilution hemofiltration. These problems include filter clotting; high filtration fraction in the presence of access dysfunction and fluctuations in blood flow; and circuit downtime during surgery, radiologic procedures, and filter changes. Equally important are the observations that this study was conducted over 6 years in a single center, uremic control was not reported, the incidence of sepsis was low compared to that of the typical populations reported to develop ARF in the world, and that its final outcome was not the accepted 28-day or 90-day mortality typically used in ICU trials. Thus, the external validity of this study remains untested.

Another prospective randomized trial conducted by Bouman et al. (27) assigned patients to three groups: (i) early high-volume hemofiltration (72 to 96 L per 24 hours); (ii) early low-volume hemofiltration (24 to 36 L per 24 hours); and (iii) late low-volume hemofiltration (24 to 36 L per 24 hours). These investigators found no difference in terms of renal recovery or 28-day mortality. Unfortunately, prescribed doses were not standardized by weight, making the potential variability in RRT dose large. Furthermore, the number of patients was small, making the study insufficiently powered, and, again, the incidence of sepsis was low compared to that of the typical populations reported to develop ARF in the world.

All of these studies, however, must be seen in the light of an absolute lack of any previous attempt to adjust ARF treatment dose to specific target levels. During the third International Course on Critical Care Nephrology held in Vicenza, Italy, a survey on various aspects of ARF was conducted, including treatment prescription, among about 550 participants (equally distributed between nephrologists and intensivists) from about 500 centers (28). More than one third of responders declared not prescribing any specific RRT dose for ARF patients, and 75% of responders did not monitor the RRT-delivered dose. In fact, although a clear understanding of the adequate dose of RRT has not yet been achieved, it is also true that, as is true for antibiotic blood levels during severe infections, adequate prescription should be followed by adequate administration. The differences between delivered and prescribed dose in patients with ARF undergoing IHD were analyzed by Evanson et al. (29). The authors found that high patient weight, male gender, and low blood flow were limiting factors affecting RRT administration, and that about 70% of dialysis delivered a Kt/V of less than 1.2. A retrospective study by Venkataraman et al. (30) also showed that, similarly, patients received only 67% of prescribed CRRT therapy. Furthermore, the use of the Adequacy Calculator allowed us (17) to strictly monitor treatments during the study period, and an average 10.7% (p <0.05) reduction of therapy delivery was found when compared to the prescribed dose. This delivery reduction was sometimes due to Calculator overestimation and, more often, to an operative treatment time that was shorter than prescribed (during bag substitution, alarms troubleshooting, and filter change, CRRT is not administered). Of note in the CVVH dose trial (26), only patients who achieved more than 85% of the prescribed dose were included. To obtain this goal, compensation for interruptions in treatment due to ICU procedures was made by increasing effluent flow rates in the subsequent hours. These observations underline that RRT prescriptions for ARF patients in the ICU should be monitored closely if one wishes to ensure adequate delivery of the prescribed dose.

Practical Aspects

During RRT, clearance depends on circuit blood flow (Qb), hemofiltration (Qf), or dialysis (Qd) flow, solute molecular weights, and hemodialyzer type and size. Qb, as a variable in delivering RRT dose, is mainly dependent on vascular access and the operational characteristics of machines used in the clinical setting. Qf is strictly linked to Qb during convective techniques by filtration fraction. Filtration fraction does not limit Qd, but when the Qd/Qb ratio exceeds 0.3, it can be estimated that dialysate will not be completely saturated by blood-diffusing solutes. The search for specific toxins to be cleared, furthermore, has not been successful despite years of research, and urea and creatinine are generally used as reference solutes to measure renal replacement clearance for renal failure. Although available evidence does not allow the direct correlation of the degree of uremia with outcome in chronic renal disease, in the absence of a specific solute, clearances of urea and creatinine blood levels are used to guide treatment dose. During UF, the driving pressure jams solutes, such as urea and creatinine, against the membrane and into the pores, depending on the membrane-sieving coefficient (SC) for that molecule. SC expresses a dimensionless value, and is estimated by the ratio of the concentration of the solutes in the filtrate divided by that in the plasma water or blood. A SC of 1.0, as is the case for urea and creatinine, demonstrates complete permeability, and a value of 0 reflects complete rejection. Molecular size over approximately 12 kd and filter porosity are the major determinants of SC. The K during convection is measured by the product of Qf times SC. Thus, different from diffusion, there is a linear relationship between K and Qf, SC being the changing variable for different solutes. During diffusion, the linear relationship is lost when Qd exceeds about one third of Qb. As a rough estimate, we can consider that during continuous low-efficiency treatments, the RRT dose is a direct expression of ultrafitrative (Qf) and dialysis (Qd), independent of which solute must be removed from blood. During continuous treatment, it has now been suggested to deliver at least a urea clearance of 2 L/hour, with the clinical evidence that 35 mL/kg/hour may be the best prescription (i.e., about 2.8 L/hour in a 70-kg patient). Other authors suggest a prescription based on patient requirements, in turn based on the urea generation rate and catabolic state of the single patient. It has been shown, however, that during continuous therapy, a clearance less than 2 L/hour will almost definitely be insufficient in an adult critically ill patient. For more exact estimations, simple computations have been shown to adequately estimate clearance (17,31). Tables 161.2 and 161.3 provide details that could be followed each time a RRT prescription is indicated.

Table 161.2 Guidelines for RRT Prescription

Clinical

Operational

Setting

Fluid balance

Net ultrafiltration

A continuous management of negative balance (100–300 mL/h) is preferred in hemodynamically unstable patients. A complete monitoring (CVC, S-G, arterial line, ECG, pulse oximeter) is recommended.

Adequacy and dose

Clearance/modality

2,000–3,000 mL/h K (or 35 mL/kg/h) for CRRT; consider first CVVHDF. If IHD is selected, a prescription of every day for 4 h is recommended. Prescribe a Kt/V >1.2.

Acid-base balance

Solution buffer

Bicarbonate buffered solutions are preferable to lactate buffered solutions in case of lactic acidosis and/or hepatic failure.

Electrolyte

Dialysate/replacement

Consider solutions without K+ in case of severe hyperkalemia. Accurately manage MgPO4.

Timing

Schedule

Early and intense RRT is suggested.

Protocol

Staff/machine

Well-trained staff should routinely use RRT monitors according to predefined institutional protocols.

CVC, central venous catheter; S-G, Swan-Ganz catheter; ECG, electrocardiogram; CRRT, continuous renal replacement therapy; CVVHDF, continuous venovenous hemodiafiltration; IHD, intermittent hemodialysis.

Table 161.3 Example of a possible prescription for continuous treatment in a 70-kg patient (VUREA: 42 L) during an ideal session of 24 hours (t: 1,440 minutes) (net ultrafiltration [patient fluid loss] is considered zero in KCALC for simplicity)

Estimated urea clearance (KCALC)

Notes

Value of Q to obtain 35 mL/kg/h

Value of Q to obtain a Kt/V of 1

CVVH postdilution

KCALC = Qrep

Always keep filtration fraction <20% (Qb must be 5 times Qrep)

Qrep: 41 mL/min or 2,450 mL/h

Qrep: 29 mL/min or 1,750 mL/h

CVVH predilution

KCALC = Quf/[1 + (Qrep/Qb)]

Filtration fraction computation changes (keep <20%)

For a Qb of 200 mL/min, Qrep: 53 mL/min or 3,200 mL/h

For a Qb of 200 mL/min, Qrep: 35 mL/min or 2,100 mL/h

CVVHD

KCALC = Qdo

Keep Qb at least thrice Qdo

Qdo: 41 mL/min or 2,450 mL/h

Qdo: 29 mL/min or 1,750 mL/h

CVVHDF postdilution (50% convective and diffusive K)

KCALC = Qrep + Qdo

Consider notes of both CVVH and CVVHD

Qrep: 20 mL/min + Qdo: 21 mL/min

Qrep: 14 mL/min replacement solution + Qdo: 15 mL/min

CVVH, continuous venovenous hemofiltration; Qrep, replacement solution flow rate; Qb, blood flow rate; Quf, ultrafiltration flow rate (Quf = Qrep + Qnet); CVVHD, continuous venovenous hemodialysis; Qdo, dialysate solution flow rate; CVVHDF, continuous venovenous hemodiafiltration; Qnet, patient's net fluid loss.
Urea volume of distribution V (L): patient's body weight (Kg) × 0.6.
Estimated fractional clearance (Kt/VCALC): KCALC (mL/min) × prescribed treatment time (min)/V (mL).
A quantity of 35 mL/kg/h roughly corresponds to a Kt/V of 1.4. A Kt/V of 1 corresponds to approximately 25 mL/kg/h.
Filtration fraction calculation (postdilution): Qrep/Qb × 100. Filtration fraction calculation (predilution): Qrep/Qb + Qrep × 100.

From Continuous to Intermittent: One Treatment Fits All?

Clearance-based dose quantification methods may not be adequate to compare effectiveness. For example, peritoneal dialysis (PD), traditionally providing less urea clearance per week than IHD, has comparable patient outcomes. Furthermore, when EKRc is used to compare intermittent and continuous therapies, it does not appear to be equivalent in terms of outcome: typically, PD patients have better outcomes with less EKRc than IHD patients (32). When the critical parameter is metabolic control, an acceptable mean blood urea nitrogen level of 60 mg/dL—easily obtainable in a 100-kg patient with a 2 L/hour CVVH in a computer-based simulation—has been shown to be very difficult to reach, even by intensive IHD regimens (31). In addition to the benefits specifically pertaining to the kinetics of solute removal, increased RRT frequency results in decreased ultrafiltration requirements per treatment. The avoidance of volume swings related to rapid ultrafiltration rates may also represent another dimension of dose where comparability is difficult.

Despite the development of new membranes, sophisticated dialysis machinery, tailored dialysate composition, and continuous dialysis therapies, a relationship with the frequency of RRT (continuous versus intermittent) delivery has not been fully established. Most recently, the Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock (33) concluded that, based on present scientific evidence, continuous RRT should be considered equivalent to IHD for the treatment of ARF. In a large comparative trial randomizing 166 critically ill patients with ARF to either CRRT or IHD, Mehta et al. (34) found that the CRRT population, despite randomization, had significantly greater severity of illness scores. This could, in part, explain why, despite better control of azotemia and a greater likelihood of achieving the desired fluid balance, CRRT had increased mortality. Another more recent smaller trial at the Cleveland Clinic (35) failed to find a difference in outcome between one therapy and another. In recent years, a meta-analysis on this issue has been unable to solve the debate of continuous versus intermittent treatment. A meta-analysis of 13 studies conducted by Kellum et al. (36) concluded that, after the stratification of 1,400 patients according to disease severity, when similar patients were compared, CRRT was associated with a significant decrease in the risk of death. However, when the same data were analyzed the same year by Tonelli et al. (37), no difference in outcome could be detected. Thus, it remains uncertain whether the choice of RRT modality (intermittent or continuous) actually matters to patient outcome. A recent randomized controlled trial comparing IHD and continuous venovenous hemodiafiltration concluded that, provided strict guidelines to improve tolerance and metabolic control are used, almost all patients with ARF as part of their multiorgan dysfunction syndrome can be treated with intermittent hemodialysis (38).

Given the lack of clear outcome data, the community of nephrologist intensivists might then consider compromise solutions. One such solution could be represented by hybrid techniques, which have been given various names such as sustained low-efficiency daily dialysis (SLEDD), prolonged daily intermittent RRT (PDIRRT), extended daily dialysis (EDD), or simply extended dialysis (39,40,41,42,43), depending on variations in schedule and type of solute removal (convective or diffusive). Theoretically speaking, the purpose of such therapy would be the optimization of the advantages offered by either CRRT or IHD, including efficient solute removal with minimum solute disequilibrium, reduced ultrafiltration rate with hemodynamic stability, optimized delivery to a prescribed ratio, low anticoagulant need, diminished cost of therapy delivery, efficiency of resource use, and improved patient mobility. Initial case series have shown the feasibility and high clearances potentially associated with such approaches. A single short-term, single-center trial comparing hybrid therapies to CRRT has shown satisfying results in terms of dose delivery and hemodynamic stability. New technology that can be used in the ICU by nurses to deliver SLEDD with convective components offers further options from a therapeutic, logistic, and cost-effectiveness point of view.

Technical Notes

RRT Modalities: Description and Nomenclature

Apart from what evidence-based medicine dictates, continuous therapies are used in 80% of ICUs worldwide, whereas intermittent hemodialysis (17%) and peritoneal dialysis (3%) have less common use (1). In the 1980s, a passionate debate between simple CAVH and complex early CVVH lasted for about 10 years, stimulating the industries to produce increasingly effective machines and monitoring systems. Accurate ultrafiltration control is now obtained by integrated roller volumetric pumps (blood, replacement dialysate, and effluent) and scales. These monitors display pressure measurements of all crucial segments of the circuit (catheter inlet and outlet, filter inlet and outlet, UF and dialysate ports). This information, integrated with adequate alarm systems, has allowed the ICU staff to increase filter efficiency and lengthen circuit patency, with the ability to detect potential sources of clotting, thereby improving patient safety. A complete monitoring of fluid balance is also provided by continuous recording of the history of the last 24 hours of treatment. When an alarm occurs, a “smart” message on the screen suggests the most appropriate intervention required. A complete range of ICU RRT therapeutic modalities includes slow continuous ultrafiltration (SCUF), continuous venovenous hemofiltration (CVVH), continuous venovenous hemodialysis (CVVHD), continuous venovenous hemodiafiltration (CVVHDF), and therapeutic plasma exchange (TPE) described below in detail (Fig. 161.5).

Intermittent Hemodialysis

Intermittent hemodialysis (IHD) is a prevalently diffusive treatment in which blood and dialysate are circulated in countercurrent mode, and generally, a low permeability, cellulose-based membrane is used. Dialysate must be pyrogen-free but not necessarily sterile, since dialysate-blood contact does not occur. The ultrafiltration rate is equal to the scheduled weight loss. This treatment can typically be performed 4 hours three times a week or daily. Our group prefers to start with Qb of 150 to 300 mL/minute; Qd, 300 to 500 mL/minute.

Figure 161.5. Schematic representation of the most common continuous renal replacement therapy (RRT) setups. A black triangle represents blood flow direction; a gray triangle indicates dialysate/replacement solutions flows. CVVH, continuous venovenous hemofiltration; CVVHD, continuous venovenous hemodialysis; CVVHDF, continuous venovenous hemodiafiltration; Di, dialysate in; Do, dialysate out; Qb, blood flow; Qd, dialysate solution flow; Qf, replacement solution flow; Quf, ultrafiltration flow; Rpost, replacement solution postfilter; Rpre, replacement solution prefilter; Uf, ultrafiltration; V-V SCUF, venovenous slow continuous ultrafiltration.

Peritoneal Dialysis

Peritoneal dialysis (PD) is a predominantly diffusive treatment in which blood circulating along the capillaries of the peritoneal membrane is exposed to dialysate. Access is obtained by the insertion of a peritoneal catheter, which allows the abdominal instillation of dialysate. Solute and water movement is achieved by means of variable concentration and tonicity gradients generated by the dialysate. This treatment can be performed continuously or intermittently.

Slow Continuous Ultrafiltration

Slow continuous ultrafiltration (SCUF) is a technique by which blood is driven through a highly permeable filter via an extracorporeal circuit in venovenous mode. The ultrafiltrate produced during membrane transit is not replaced and corresponds to weight loss. It is used only for fluid control in overloaded patients (i.e., congestive heart failure patients who do not respond to diuretic therapy). Our group prefers to start with Qb of 100 to 250 mL/minute; Quf, 5 to 15 mL/minute.

Continuous Venovenous Hemofiltration

Continuous venovenous hemofiltration (CVVH) is a technique by which blood is driven through a highly permeable filter via an extracorporeal circuit in venovenous mode. The ultrafiltrate produced during membrane transit is replaced, in part or completely, to achieve blood purification and volume control. If replacement fluid is delivered after the filter, the technique is defined as postdilution hemofiltration. If it is delivered before the filter, the technique is defined as predilution hemofiltration. The replacement fluid can also be delivered both prefilter and postfilter. Clearance for all solutes is convective and equals the ultrafiltration rate. Our group prefers to start with Qb of 100 to 250 mL/minute; Quf, 15 to 60 mL/minute.

Continuous Venovenous Hemodialysis

Continuous venovenous hemodialysis (CVVHD) is a technique by which blood is driven through a low-permeability dialyzer via an extracorporeal circuit in venovenous mode, and a countercurrent flow of dialysate is delivered in the dialysate compartment. The ultrafiltrate produced during membrane transit corresponds to the patient's weight loss. Solute clearance is mainly diffusive, and efficiency is limited to small solutes only. Our group prefers to start with Qb of 100 to 250 mL/minute; Qd, 15 to 60 mL/minute.

Continuous Venovenous Hemodiafiltration

Continuous venovenous hemodiafiltration (CVVHDF) is a technique by which blood is driven through a highly permeable dialyzer via an extracorporeal circuit in venovenous mode, and a countercurrent flow of dialysate is delivered in the dialysate compartment. The ultrafiltrate produced during membrane transit is in excess of the patient's desired weight loss. A replacement solution is needed to maintain fluid balance. Solute clearance is both convective and diffusive. Our group prefers to start with Qb of 100 to 250 mL/minute; Qd, 15 to 60 mL/minute; Qf, 15 to 60 mL/minute.

Hemoperfusion

By hemoperfusion (HP), blood is circulated on a bed of coated charcoal powder to remove solutes by adsorption. The technique is specifically indicated in cases of poisoning or intoxication with agents that can be effectively removed by charcoal. This treatment may cause platelet and protein depletion.

Plasmapheresis

Plasmapheresis (PP) is a treatment that uses specific plasmafilters. Molecular-weight cutoff of the membrane is much higher than that of hemofilters (100,000 to 1,000,000 kd); plasma as a whole is filtered and blood is reconstituted by the infusion of plasma products such as frozen plasma or albumin. This technique is performed to remove proteins or protein-bound solutes.

High-flux Dialysis

High-flux dialysis (HFD) is a treatment that uses highly permeable membranes in conjunction with an ultrafiltration control system. Due to the characteristics of the membrane, ultrafiltration occurs in the proximal part of the filter that is counterbalanced by positive pressure applied to the dialysate compartment. This causes, in the distal part of the filter, a phenomenon called backfiltration, which is the convective passage of the dialysate into the blood. Diffusion and convection are combined, but due to the use of a pyrogenfree dialysate, replacement is avoided.

High-volume Hemofiltration

High-volume hemofiltration (HVHF) is a treatment that uses highly permeable membranes and hemofiltration with a high volume setting. Our suggested settings are Qb >200 mL/minute and Qf >45 mL/kg/hour (44).

High-permeability Hemofiltration

High-permeability hemofiltration (HPHF) is a treatment that uses high-cutoff (60 kd) permeable membranes and hemofiltration. High treatment flows are not necessary, but strict control of bigger molecules, like albumin, is recommended (45).

Anticoagulation

The need for anticoagulation of the CRRT circuit arises from the fact that the contact between blood and the tubing of the circuit and the membrane of the filter induces activation of the coagulation cascade. This extracorporeal activation inevitably results in filter or circuit clotting. It is evident that the anticoagulation strategy will change depending on the prescribed RRT schedule, being a priority feature of continuous treatments where blood–artificial surface interaction is maximized. The aims of anticoagulation are as follows: maintenance of extracorporeal circuit and dialyzer patency; reduction of off-treatment time (downtime) that could have a clinical impact on the overall RRT clearance; reduction of treatment cost by the use of as little material as possible; and achievement of the above aims with minimal risk for the patient. This last concept should perhaps be the first to rule anticoagulation management: under no circumstances should the patient be put at risk of bleeding to prolong circuit life.

Circuit Setup Optimization and No Anticoagulation

Several technical features of the RRT circuit are likely to affect the success of any anticoagulant approach. Vascular access must be of adequate size; tubing kinking should be avoided; blood flow rate should exceed 100 mL/minute; pump flow fluctuations must be prevented (in modern machines this event is mainly due to increased circuit resistances rather than flow rate inaccuracies); and venous bubble trap, where air/blood contact occurs, must be accurately monitored. Another component of circuit setup has to be addressed: the plasma filtration fraction should be kept as far as possible below 20%, and when possible or considered correct, predilutional hemofiltration should be selected. There is evidence that, when setup is perfectly optimized, anticoagulants are only a relatively minor component of circuit patency; in fact, whenever the patient's clinical features present risk factors for bleeding (prolonged clotting times, thrombocytopenia), RRT can be safely performed without the use of any anticoagulant (46).

Unfractionated Heparin

Unfractionated heparin (UFH) is a commonly available anticoagulant. It is easy to use, and an antidote is available (protamine). Heparin doses generally range from 5 to 10 IU/kg/hour. In patients with very limited circuit duration, it can also be used in combination with protamine (regional heparinization), with a 1:1 ratio (150 IU of UFH per mg of protamine) and a strictly monitored activated prothrombin time (aPTT). The problem with UFH is its relatively unpredictable bioavailability, the necessity for antithrombin III (ATIII) level optimization, and the occurrence of heparin-induced thrombocytopenia (HIT).

Low-molecular-weight Heparins

Some centers have gained experience with low-molecular-weight heparins (LMWH)s, a relatively new kind of anticoagulant. Prospective studies have not yet shown these to be superior to prolong circuit life. These molecules appear to have a better bioavailability than UFH and a lower incidence of HIT with a 10% increased cost.

Prostacyclin

Prostacyclin (PGI2) is a potentially useful drug for RRT anticoagulation, being the most potent inhibitor of platelet aggregation with the shortest half-life. PGI2 is infused at a dose of 4 to 8 ng/kg/hour, with or without the adjunct of a low dose of UFH. Hypotension may be induced by higher doses of PGI2. Some studies have demonstrated PGI2 efficacy, but its high cost and harmful side effects might limit the use of this agent to patients with short circuit duration (47).

Citrate

Citrate provides a form of regional anticoagulation that depends on the ability of citrate to chelate calcium. The chelation of calcium prevents clot formation. Briefly, a calciumfree sodium citrate containing replacement solution and/or dialysate solution is prepared and administered at the appropriate rate to achieve the desired activated PTT (aPTT) (60 to 90 seconds). Calcium chloride is then administered to replace chelated/dialyzed calcium and maintain normocalcemia. This approach is effective in maintaining excellent filter patency and compares favorably with heparin. It also avoids the risk for HIT and does not lead to systemic anticoagulation. The relative drawbacks of this anticoagulation management strategy include the risk for hypocalcemia and metabolic alkalosis, and the use of cumbersome replacement/dialysate fluid preparation (48,49).

Other Strategies

Alternatives to the techniques presented above are listed in Table 161.4 for completeness.

Vascular Access

The fundamental role played by vascular access must be emphasized. In fact, circuit failure is more often due to inadequate vascular access than insufficient anticoagulation. Thus, the optimal dialysis catheter can save the patient from inappropriate increases of the anticoagulation dose. Venovenous RRT relies on the use of a temporary double-lumen catheter. Such catheters are inserted in a central vein and available in different brands, shapes, and sizes (Fig. 161.6). The site of insertion of double-lumen catheters implies several considerations (clinician expertise, body habitus of the patient, the presence of other intravenous catheters). The femoral vein is generally the first choice of vascular access; internal jugular or subclavian accesses are often associated with inadequate performance, and the inguinal puncture is safer and easier to perform in coagulopathic critically ill patients. A valid alternative may be achieved by cannulation of the right jugular internal vein with the tip of the catheter reaching the right atrium; circuit blood flow rates with this approach can reach 300 mL/minute. Catheter sizes for adult patients range from 12 to 14 French and length from 16 to 25 cm; the bigger and shorter the catheter, the higher the performance. Nonetheless, when the femoral vein is selected, a 20-cm-long catheter has its tip positioned close to the inferior vena cava, allowing optimal flows within the circuit. When an inadequate blood flow or a catheter malfunction is suspected, venous and arterial lumens should be flushed with saline, with the goal of testing resistance to injection and aspiration. Limb clotting of the line versus kinking due to the patient's position must be distinguished. In the first case, a switching of arterial and venous limb can be attempted. This maneuver increases circuit recirculation, but clinical consequences are negligible. In the second case, a heparin or urokinase lock can be tried for a few hours. Another approach is a catheter (guidewire) exchange.

Table 161.4 Anticoagulation strategies

Drug

PRO

CON

No anticoagulation

High risk of bleeding in patients

Relatively shorter circuit life span

Unfractionated heparin

Routine

HIT

Low-molecular-weight heparin

Routine (alternative to UH)

HIT

Prostacyclin

Very short circuit life span

Hypotension

Citrate

Routine/very short circuit life span

Hypocalcemia

Danaparoid

HIT

Insufficient data available

Argatroban

HIT

Insufficient data available

Irudine

HIT

Insufficient data available

Nafamostat mesilate

HIT

Insufficient data available

Heparin-coated circuits

Routine

Insufficient data available

HIT, heparin-induced thrombocytopenia; UH, unfractionated heparin.

Figure 161.6. Representation of some double-lumen catheter shapes and details of blood intake and outflow on their tips

Perspective for the Future

The ideal RRT machine for the future should self-set the right RRT technique, modality, and prescription after the clinician has provided all the information for the specific patient. Monitors and materials of the future will further increase ease of use, safety measures, and the accuracy of each component of the integrated system, reducing the labor involved. The minimal safety standards should allow operators to manually control circuit pressure, de-aerate the chamber and/or bubble sensor and integrated ultrafiltration, with the possibility of consulting/saving the history of treatment settings, events, and pressure trends. However, when described features and alarms are manipulated by human operators, the opportunity for errors will always be present. Physicians and nurses involved in the prescription and delivery of RRT should have precise protocols and defined procedure checkpoints to prevent major clinical problems. Unfortunately, there is no solution to the unwise use of a perfect system (50).

The Role of Renal Replacement Therapies in Different Settings

Sepsis and Multiple Organ Dysfunction Syndrome

Great interest has arisen in the last 10 years concerning extracorporeal blood purification therapies (EBPT) as adjuvants in the complex therapy of sepsis and multiple organ dysfunction syndrome (MODS). RRT was the first and still is the most used and effective type of EBPT. Evidence is growing about its ability to maintain homeostatic balance in critically ill patients—specifically, septic patients with MODS. Clinical trials have been recently designed to modify or improve these therapies. Beyond correcting specific uremic toxins, RRT seems to restore other physiologic homeostatic mechanisms (renal dose of CRRT); at overdoses, it may play a role in blood purification from water-soluble cytokines produced during systemic inflammatory and septic states (sepsis dose). This concept leads to speculation that higher-volume hemofiltration may be beneficial in septic patients beyond the removal of classic markers, and if an UF rate of 1,400 to 2,400 mL/hour for a 70-kg man (equivalent to 20 to 35 mL/kg/hour) can be considered as a traditional dose, then increasing effluent production to more than 45 mL/kg/hour can be considered as high-volume CVVH. Based on this speculation, a further increase in UF has been suggested, and high-volume hemofiltration (HVHF) protocols have been developed by several authors. Unlike with purely continuous therapies, one of the main challenges of HVHF is the technical limit of currently available machines (UF ranges from 4 L/hour to 9 or 10 L/hour), so that sessions are often intermittent or interrupted by traditional CVVH after 2 to 8 hours. Animal models of severe sepsis (51,52,53) clearly demonstrated a beneficial effect of HVHF on hemodynamics, proportional to the intensity of ultrafiltration. These experiments have triggered great interest in HVHF as a potential “ideal model of therapy to be started when endotoxemia is present or suspected, or even before it occurs” (53). In the experimental setting, the UF rate is increased up to a level equivalent to 12 L/hour in a 70-kg human being. Journois et al. (54) conducted a randomized controlled study of zero-balanced HVHF in 20 children (UF rate equivalent to 7 to 9 L/hour in a 70-kg adult) undergoing cardiac surgery and demonstrated a significant reduction in postoperative blood loss, time to extubation, and improvements in alveolar-arterial oxygen gradient. The first reports of application of HVHF to the treatment of septic shock in humans with MODS have appeared recently. Lonnemann (55) demonstrated a beneficial effect on macrophage function with restoration of the ability to produce tumor necrosis factor-β (TNF-β) in response to endotoxin exposure, showing the potential of EBPT for immunomodulation at a cellular and humoral level in sepsis. Oudemans-van Straaten et al. (56) conducted a prospective cohort analysis in 306 patients who received HVHF at a mean UF rate of 4 L/hour. They found an improvement in cardiac index (CI), blood pressure (BP), and stroke volume (SV) in hypodynamic patients, and increase in systemic venous resistance (SVR) with a decrease in dopamine dose in those who were hyperdynamic. Honore et al. (57) evaluated the effects of short-term, high-volume hemofiltration (STHVH). Sessions lasted 4 hours with 9 L/hour hemofiltration flow and were followed by conventional CVVH in 20 patients affected by intractable cardiocirculatory failure resulting from severe septic shock. Eleven patients (“responders”) attained all therapeutic end points (increase in CI; increase in mixed venous saturation; increase in arterial pH; reduction in epinephrine dose). The rate of survival to 28 days in this group was markedly higher (9 of 11) than among nonresponders (0 of 9). Cole et al. (58) measured hemodynamics, serum cytokines, and complement concentration in 11 patients with septic shock and MODS. Patients were randomly assigned to HVHF (8 h at 6 L/hour) or to standard CVVH. The decrease in vasopressor requirement was significantly higher in the HVHF group. Cole et al. also noted that in the HVHF group, the concentration of the measured soluble mediators in the ultrafiltrate was negligible, indicating a greater role in filter adsorption of studied mediators.

All of these data support the hypothesis that HVHF techniques are safe and feasible but, above all, show that adequate blood purification can restore and maintain cardiac and circulatory function as well as metabolic and gas exchange parameters. However, large randomized trials are still lacking, and these types of therapies are still far from becoming routine (59).

A more complex evolution of EBPT, combining the need for high sieving coefficients of larger molecules and continuous therapy, led to a technique called coupled plasma filtration adsorption (CPFA) (60,61). This technique separates plasma from blood using a plasma filter; the plasma is then passed through a synthetic resin cartridge and returned to the blood. A second blood filter is used to remove excess fluid and low-molecular-weight toxins. The resin was chosen based on its adsorption capacity for important inflammatory mediators, low levels of extractable toxins, and good pressure flow performance. In a randomized clinical trial, the adsorbent removed almost 100% of TNF-α and interleukin-β (IL-β), allowing a significant reduction of vasopressor dosage when compared to CVVH alone.

Congestive Heart Failure

Fluid overload may occur in patients with congestive heart failure. Under normal conditions, this is treated with inotropic support and diuretics. However, when diuretics fail, fluid removal becomes uncontrolled, and other therapeutic options must be undertaken. Extracorporeal ultrafiltration is a possible solution to restore the status of fluid balance close to normal. Several new technologies have made ultrafiltration available today in all centers and are easy to institute. Acute isolated schedules of ultrafiltration may, however, be too aggressive and could result in severe hemodynamic instability. For this reason, continuous extracorporeal techniques have been applied in such patients, and the therapy is generally carried out with success. Excellent hemodynamic stability, a good cardiovascular response, and, often, diuresis restoration are the most common effects encountered using continuous forms of extracorporeal fluid removal.

One specific comment must be made concerning the difference between CVVH and all other techniques, including dialysis and the use of diuretics. In all pharmacologic and dialytic techniques, the removal of sodium and water cannot be dissociated, and the mechanisms are strictly correlated. In particular, the diuretic effect is based on a remarkable natriuresis, while ultrafiltration during dialysis may result in hypotonia or hypertonia, depending on the interference with diffusion and removal of other molecules such as urea and other electrolytes. In such circumstances, water removal is linked to other solutes in proportions that are dependent on the technique used. In SCUF, the mechanism of ultrafiltration produces a fluid that is substantially similar to plasma water except for a minimal interference due to Donnan effects. In such a technique, ultrafiltration is basically iso-osmotic and isonatremic, and water and sodium removal cannot be dissociated, with sodium elimination linked to the sodium plasma water concentration. In CVVH and hemofiltration in general, the ultrafiltrate composition is definitely similar to plasma water, but the sodium balance can be significantly affected by the sodium concentration in the replacement solution. Sodium removal can be dissociated from water removal in CVVH, thus obtaining a real manipulation of the sodium pool in the body. This effect cannot be achieved with any other technique. The advantage is that not only plasma concentrations can be normalized but also the electrolyte content in the extracellular—and possibly intracellular—volume (62).

Contrast-induced Nephropathy

Radiocontrast-induced nephropathy (RCIN) causes acute kidney injury and increases mortality. Several studies have examined the capacity of various forms of extracorporeal blood purification therapies for the prevention of RCIN, with conflicting results. A recent systematic review of published trials to determine whether periprocedural extracorporeal blood purification prevents RCIN revealed that the incidence of RCIN, defined as an increase in serum creatinine concentration (>0.5 mg/dL [>44 mmol/L]), was 35.2% in the standard medical therapy group and 27.8% in the extracorporeal blood purification group. Extracorporeal blood purification did not decrease the incidence of RCIN significantly as compared with standard medical therapy (risk ratio, 0.97; 95% confidence interval, 0.44–2.14); however, the patients' heterogeneity was high. Limiting analysis to only randomized trials did not eliminate heterogeneity, but limiting analysis to only hemodialysis trials did. Periprocedural hemodialysis did not decrease the incidence of RCIN (63).

RRT for Children

There are some important differences in the RRT indications, methods, and prescription between children and adult patients; nevertheless, the technique is essentially the same. The main indication is the correction of water overload; different from the adult setting, where solute control may play a key role, it has been shown that restoring adequate water content in small children is the main independent variable for outcome prediction (64,65). This concept is much more important in critically ill, smaller children, in whom a relatively larger amount of fluid must be administered to deliver an adequate amount of drug infusion, parenteral/enteral nutrition, blood derivates, and so on. Corrections of acid-base imbalance and electrolyte disorders are also strong indications for RRT prescription in children. Catheter size ranges from 6.5 French (10 cm long) for patients weighing less than 10 kg to 8 French (15 cm long) for patients weighing 11 to 15 kg. Blood priming may be indicated if more than 8 mL/kg of patient's blood volume are necessary to fill a RRT circuit. Full anticoagulation must always be maintained to avoid excessive blood loss in case of circuit clotting. Predilution hemofiltration is generally the preferred modality and is delivered in a continuous fashion. Fluid balance requires strict monitoring and highest accuracy due to the risk of excessive patient dehydration. Prescription of RRT clearance should be titrated based on the patient body surface area, an approach that will usually lead to relatively higher doses for small children with respect to adult patients when considered per kilogram (66). Critically ill children weighing below 10 kg and neonates with ARF are often treated with peritoneal dialysis (PD); this discussion goes beyond the scope of this chapter. An important exception to this general approach is the case of children with ARF during an extracorporeal membrane oxygenation treatment (ECMO). In this case, the RRT circuit is placed in parallel to the ECMO circuit, and it is possible to let a significant blood flow run into the filter even in the smallest patients.

Summary

The mechanisms involved in RRT are founded on the principle of water and solute transport according to two fundamental mechanisms: diffusion and convection. These mechanisms can be applied to clinical practice as different techniques (intermittent, extended, or continuous RRT) and modalities (hemofiltration, hemodialysis, hemodiafiltration, plasmafiltration, hemoperfusion, coupled plasmafiltration and adsorption). A precise understanding of technical and clinical implications of such therapies seems important in deriving a correct RRT prescription since, so far, no consensus exists about which modality should be administered to critically ill patients with ARF. Different RRT prescriptions, modalities, and schedules can be administered to critically ill patients with acute kidney injury. Clinical effects on critically ill patients depend on the selected RRT strategy and on the severity/complexity of the patient's clinical picture. Modern versatile machines and flexible operative prescriptions allow the operators to range from highly intermittent high-efficiency therapies to slow continuous hemofiltration, depending on the patient's hemodynamic stability, fluid balance needs, acid-base balance, and electrolyte derangements. A specific dose of RRT has not been adopted in clinical practice; a standard dose prescription and strict control of the delivered dose should be monitored if one wishes to ensure the adequate delivery of a prescribed dose. The best evidence to date supports a renal replacement therapy dose of at least 35 mL/kg/hour—spKt/V of 1.4—for CVVH, CVVHDF, or daily IHD.

Acknowledgments

Dr. Zaccaria Ricci wishes to thank Dr. Stefano De Paulis from the Cardiac Surgery Department of Cardiovascular Medicine, Division of Cardiac Anesthesia and Intensive Care, Policlinico Gemelli, Università Cattolica del Sacro Cuore, Rome, Italy, for his highly valued critical revision of the manuscript.

References

1. Uchino S, Kellum JA, Bellomo R, et al., for the Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) Investigators. Acute renal failure in critically ill patients: a multinational, multicenter study. JAMA. 2005;294:813–818.

2. Bellomo R. The epidemiology of acute renal failure: 1975 versus 2005. Curr Op Crit Care. 2006;12:557–560.

3. Bagshaw SM, Laupland KB, Doig CJ, et al. Prognosis for long-term survival and renal recovery in critically ill patients with severe acute renal failure: a population-based study. Crit Care. 2005,9:R700–R709.

4. Kramer P, Wigger W, Rieger J, et al. Arteriovenous haemofiltration: a new simple method for treatment of overhydrated patients resistant to diuretics [in German]. Klin Wochenschr. 1977;55:1121–1122.

5. Burchardi H. Renal replacement therapy in the ICU: criteria for initiating RRT. Contrib Nephrol. 2001;132:171–180.

6. Bellomo R, Ronco C, Kellum JA, et al., and the ADQI workgroup. Acute renal failure—definition, outcome measures, animal models, fluid therapy and information technology needs: the Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group. Crit Care. 2004;8:R204–R212.

7. Hoste EAJ, Kellum JA. Acute kidney injury: epidemiology and diagnostic criteria. Curr Op Crit Care. 2006;12:531–537.

8. Ronco C, Bellomo R. Principles of solute clearance during continuous renal replacement therapy. In: Critical Care Nephrology. Philadelphia, PA: Kluwer Academic Publishers; 1213–1223.

9. Cole L, Bellomo R, Davenport P, et al. Cytokine removal during continuous renal replacement therapy: an ex vivo comparison of convection and diffusion. Int J Artif Organs. 2004;27(5):388–397.

10. Ricci Z, Ronco C, Bachetoni A, et al. Solute removal during continuous renal replacement therapy in critically ill patients: convection versus diffusion. Crit Care. 2006;10:R67.

11. Owen W, Lew N, Liu Y, et al. The urea reduction ratio and serum albumin concentrations as predictors of mortality in patients undergoing hemodialysis. N Engl J Med. 1993;329:1001–1006.

12. Collins AJ, Ma JZ, Umen A, et al. Urea index and other predictors of long term outcome in hemodialysis patient survival. Am J Kidney Dis. 1994;23:272–282.

13. Hakim R, Breyer J, Ismail N, et al. Effects of dose of dialysis on morbidity and mortality. Am J Kidney Dis. 1994;23:661–669.

14. Parker T, Hushni L, Huang W, et al. Survival of hemodialysis patients in the United States is improved with a greater quantity of dialysis. Am J Kidney Dis. 1994;23:670–680.

15. Eknoyan G, Levin N. NKF-K/DOQI clinical practice guidelines: update 2000. Am J Kidney Dis. 2001;38:917.

16. Arabed G, Knoyan E, Erald G, et al. Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med. 2002;347:2010–2019.

17. Ricci Z, Salvatori G, Bonello M, et al. In vivo validation of the adequacy calculator for continuous renal replacement therapies. Crit Care. 2005;9:R266–R273.

18. Pisitkun T, Tiranathanagul K, Poulin S, et al. A practical tool for determining the adequacy of renal replacement therapy in acute renal failure patients. Contrib Nephrol. 2004,144:329–349.

19. Gotch FA. Daily dialysis is a complex therapy with unproven benefits. Blood Purif. 2001;19:211–216.

20. Casino FG, Lopez T. The equivalent renal clearance: a new parameter to assess dialysis dose. Nephol Dial Transplant. 1996;11:1574–1581.

21. Gotch FA. The current place of urea kinetic modelling with respect to different dialysis modalities. Nephrol Dial Transplant. 1998;13(Suppl 6):10–14.

22. Himmelfarb J, Evanson J, Hakim RM, et al. Urea volume of distribution exceeds total body water in patients with acute renal failure. Kidney Int. 2002;61:317–323.

23. Brause M, Neumann A, Schumacher T, et al. Effect of filtration volume of continuous venovenous hemofiltration in the treatment of patients with acute renal failure in intensive care units. Crit Care Med. 2003;31:841–846.

24. Paganini EP, Tapolyai M, Goormastic M, et al. Establishing a dialysis therapy/patient outcome link in intensive care unit/acute dialysis for patients with acute renal failure. Am J Kidney Dis. 1996;28(Suppl 3):S81–S89.

25. Schiffl H, Lang SM, Fischer R. Daily hemodialysis and the outcome of acute renal failure. N Engl J Med. 2002;346:305–310.

26. Ronco C, Bellomo R, Homel P, et al. Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trial. Lancet. 2000;356:26–30.

27. Bouman C, Oudemans-van Straaten H, Tijssen J, et al. Effects of early high-volume continuous veno-venous hemofiltration on survival and recovery of renal function in intensive care patients with acute renal failure: a prospective randomized trial. Crit Care Med. 2002;30:2205–2211.

28. Ricci Z, Ronco C, D'amico G, et al. Practice patterns in the management of acute renal failure in the critically ill patient: an international survey. Nephrol Dial Transplant. 2006;21(3):690–696.

29. Evanson JA, Himmelfarb J, Wingard R, et al. Prescribed versus delivered dialysis in acute renal failure patients. Am J Kidney Dis. 1998;32:731–738.

30. Venkataraman R, Kellum JA, Palevsky P. Dosing patterns for CRRT at a large academic medical center in the United States. J Crit Care. 2002;17:246–250.

31. Clark WR, Mueller BA, Kraus MA, et al. Renal replacement quantification in acute renal failure. Nephrol Dial Transplant. 1998;13(Suppl 6):86–90.

32. Depner TA. Benefits of more frequent dialysis: lower TAC at the same Kt/V. Nephrol Dial Transplant. 1998;13(Suppl 6):20–24.

33. Dellinger RP, Carlet JM, Masur H, et al. Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock. Crit Care Med 2004;32:858–873.

34. Mehta RL, McDonald B, Gabbai FB, et al. A randomized clinical trial of continuous versus intermittent dialysis for acute renal failure. Kidney Int. 2001;60:1154–1163.

35. Augustine JJ, Sandy D, Seifert TH, et al. A randomized controlled trial comparing intermittent with continuous dialysis in patients with ARF. Am J Kidney Dis. 2004;44:1000–1007.

36. Kellum J, Angus DC, Johnson JP, et al. Continuous versus intermittent renal replacement therapy: a meta-analysis. Intensive Care Med. 2002;28:29–37.

37. Tonelli M, Manns B, Feller-Kopman D. Acute renal failure in the intensive care unit: a systematic review of the impact of dialytic modality on mortality and renal recovery. Am J Kidney Dis. 2002;40:875–885.

38. Vinsonneau C, Camus C, Combes A, et al., for the Hemodiafe Study Group. Continuous venovenous haemodiafiltration versus intermittent haemodialysis for acute renal failure in patients with multiple-organ dysfunction syndrome: a multicentre randomised trial. Lancet. 2006;368:379–385.

39. Butler R, Keenan SP, Inman KJ, et al. Is there a preferred technique for weaning the difficult-to-wean patient? A systematic review of the literature. Crit Care Med. 1999;27:2331–2336.

40. Marshall MR, Golper TA, Shaver MJ, et al. Urea kinetics during sustained low efficiency dialysis in critically ill patients requiring renal replacement therapy. Am J Kidney Dis. 2002;39:556–570.

41. Naka T, Baldwin I, Bellomo R, et al. Prolonged daily intermittent renal replacement therapy in ICU patients by ICU nurses and ICU physicians. Int J Artif Organs. 2004;27:380–387.

42. Kumar VA, Craig M, Depner T, et al. Extended daily dialysis: a new approach to renal replacement for acute renal failure in the intensive care tnit. Am J Kidney Dis. 2000;36:294–300.

43. Kielstein JT, Kretschmer U, Ernst T, et al. Efficacy and cardiovascular tolerability of extended dialysis in critically ill patients: a randomized controlled study. Am J Kidney Dis. 2004;43:342–349.

44. Bellomo R, Baldwin I, Ronco C. High volume vemofiltration. Contrib Nephrol. 2001;132:375–382.

45. Morgera S, Haase M, Kuss T, et al. Pilot study on the effects of high cutoff hemofiltration on the need for norepinephrine in septic patients with acute renal failure. Crit Care Med. 2006;34(8):2099–2104.

46. Tan HK, Baldwin I, Bellomo R. Continuous veno-venous hemofiltration without anticoagulation in high-risk patients. Intensive Care Med. 2000;26:1652–1657.

47. Fiaccadori E, Maggiore U, Rotelli C, et al. Continuous haemofiltration in acute renal failure with prostacyclin as the sole anti-haemostatic agent. Intensive Care Med. 2002;28:586–593.

48. Kutsogiannis DJ, Gibney N, Stollery D, et al. Regional citrate versus systemic heparin anticoagulation for continuous renal replacement in critically ill patients. Kidney Int. 2005;67:2361–2367.

49. Monchi M, Berghmans D, Ledoux D, et al. Citrate vs. heparin for anticoagulation in continuous venovenous hemofiltration: a prospective randomized study. Intensive Care Med. 2004;30:260–265.

50. Ronco C, Ricci Z, Bellomo R, et al. Management of fluid balance in CRRT: a technical approach. Int J Artif Organs. 2005;28(8):765–776.

51. Groodendorst AF. High volume hemofiltration improves haemodynamics of endotoxin-induced shock in the pig. J Crit Care. 1992;7:67–75.

52. Rogiers P. Continuous veno-venous hemofiltration improves cardiac performance by mechanism other than tumor necrosis factor alpha attenuation during endotoxic shock. Crit Care Med. 1999;27:1848–1855.

53. Bellomo R. The effect of intensive plasma water exchange by hemofiltration on haemodynamics and soluble mediators in canine endotoxemia. Am J Respir Crit Care. Med. 2000;161:1429–1436.

54. Journois D, Israel-Biet D, Pouard P, et al. High volume, zero-balanced hemofiltration to reduce delayed inflammatory response to cardiopulmonary bypass in children. Anesthesiology. 1996;85:965–976.

55. Lonneman G: Tumor necrosis factor alpha during continuous high-flux hemodialysis in sepsis with acute renal failure. Kidney Int. 1999;56:S84–S87.

56. Oudemans-van Straaten HM, Bosman RJ, van der Spoel JI, et al. Outcome of critically ill patients treated with high volume hemofiltration: a prospective cohort analysis. Intensive Care Med. 1999;25:814–821.

57. Honore PM, Jamez J, Wauthier M, et al. Prospective evaluation of short-term, high volume isovolemic hemofiltration on the hemodynamic course and outcome in patients with intractable circulatory failure resulting from septic shock. Crit Care Med. 2000;28(11):3581–3587.

58. Cole L, Bellomo R, Journois D, et al. High-volume hemofiltration in human septic shock. Intensive Care Med. 2001;27:978–986.

59. Cole L, Bellomo R, Hart G, et al. A phase II randomized, controlled trial of continuous hemofiltration in sepsis. Crit Care Med. 2002;30:100–106.

60. Ronco C, Brendolan A, Lonnemann G, et al. A pilot study of coupled plasma filtration with adsorption in septic shock. Crit Care Med. 2002;30(6):1250–1255.

61. Formica M, Olivieri C, Livigni S, et al. Hemodynamic response to coupled plasmafiltration-adsorption in human septic shock. Intensive Care Med. 2003;29:703–708.

62. Ronco C, Ricci Z, Bellomo R, et al. Extracorporeal ultrafiltration for the treatment of overhydration and congestive heart failure. Cardiology. 2001;96:155–168.

63. Cruz D, Perazella MA, Bellomo R, et al. Extracorporeal blood purification therapies for prevention of radiocontrast-induced nephropathy: a systematic review. Am J Kidney Dis. 2006;48:361–371.

64. Goldstein SL, Currier H, Graf C, et al. Outcome in children receiving continuous veno-venous hemofiltration. Pediatrics. 2001;107:1309–1312.

65. Foland JA, Fortenberry JD, Warshaw BL, et al. Fluid overload before continuous hemofiltration and survival in critically ill children: a retrospective analysis. Crit Care Med. 2004;32:1771–1776.

66. Brophy PD, Bunchman TE. References and overview for hemofiltration in pediatrics and adolescents. www.pcrrt.com. Accessed August 25, 2006.



If you find an error or have any questions, please email us at admin@doctorlib.org. Thank you!